Excerpts from the ECOLAB stability test (01.04.08) on IMOS Solidchem reflectors

Execution:
- Insertion of the IMOS Solidchem reflectors into various
cleaning solutions and cleaning concentrates
- Temperature: 20, 60 or 80°C
- Duration: 2 weeks
- After 2 weeks the reflectors are rinsed with deionised
water and optically and gravimetrically assessed.

 
   
   
   
   
   
   
   
   
   
   
   
   
   
 
   
   
back  
Concentrate cleaner at RT
Product/
concentration
T [°C] Suitability
P3-cosa CIP 72 20 +
P3-cosa CIP 77 20 +
P3-cosa CIP 90 20 +
P3-cosa CIP 92 20 +
P3-cosa CIP 95 20 +
P3-cosa PUR 80 20 +
P3-cosa PUR 83 20 +
P3-cosa PUR 84 20 +
P3-cosa PUR 85 20 +
P3-cosa PUR 88 20 +
P3-cosa FOAM 40 20 +
P3-cosa DES 20 +
P3-cosa FLUX 22 20 +
P3-cosa FLUX 33 20 +
P3-cosa FLUX 44 20 +
P3-cosa FLUX 55* 20 0
+ = suitable
0 = partly suitable
- = not suitable
* = contains nitric acid
4% cleaning solution at 60 / 80°C
Product/
concentration
T [°C] Suitability
P3-cosa CIP 72 60 +
P3-cosa CIP 77 80 +
P3-cosa CIP 90 80 +
P3-cosa CIP 92 80 +
P3-cosa CIP 95 80 +
P3-cosa PUR 80 80 +
P3-cosa PUR 83 80 +
P3-cosa PUR 84 80 +
P3-cosa PUR 85 80 +
P3-cosa PUR 88 80 +
P3-cosa FOAM 40 80 +
P3-cosa DES 80 +
P3-cosa FLUX 22 80 +
P3-cosa FLUX 33 80 +
P3-cosa FLUX 44 80 +
P3-cosa FLUX 55* 80 0
+ = suitable
0 = partly suitable
- = not suitable
* = contains nitric acid